1

Is your home a heat trap in summer?

Free 60-second test of the regulatory EPC summer comfort indicator (order of 31 March 2021, annex 9) — from your DPE number, your address or your XML file.

FreeOfficial annex 9 ruleNo account needed
46.5%

of homes come out "insufficient" once annex 9 is recalculated — against 40.2% declared on the EPC.

OneDpe measurement on 9,663,670 EPCs carrying the indicator (ADEME base, August 2026) — unadjusted data: it does not represent the entire French housing stock.

The 5 criteria of the summer comfort indicator

The indicator rests on five criteria defined by the French order of 31 March 2021, annex 9. Two are eliminatory: if either is missing, summer comfort is "insufficient" regardless of the rest. The three secondary criteria then split the "medium" and "good" levels.

  • Eliminatory criterion

    External solar protections

    Shutters, blinds or overhangs placed outside the windows facing south, east and west. They stop solar radiation before it crosses the glazing: without them, the home heats up even when well insulated.

  • Eliminatory criterion

    Roof insulation

    Insulation of the upper floor, loft or flat roof. The roof is the surface most exposed to the sun; an uninsulated roof transmits heat straight into the living rooms under the eaves.

  • Secondary criterion

    Thermal inertia

    The ability of heavy materials (thick walls, concrete slab) to store the coolness of the night and release it during the day. High inertia smooths temperature peaks; a lightweight build overheats quickly.

  • Secondary criterion

    Dual-aspect layout

    Windows on at least two façades of different orientation, allowing natural cross-ventilation. Opening up at night creates a refreshing draught that flushes out the accumulated heat.

  • Secondary criterion

    Fixed ceiling fans

    Permanently installed ceiling fans. They do not cool the air but speed up its movement, lowering the felt temperature by two to three degrees for a minimal power draw.

Combination rule (annex 9): both eliminatory criteria must be satisfied, then at least two of the three secondary criteria to reach the "good" level — otherwise "medium".

See the full methodology

What the regulatory indicator does not look at

We analysed 11.2 million certificates to understand what the summer comfort indicator really says — and what it leaves out. Two findings came out of it.

First finding: the completion gap is smaller than it looks

The indicator has appeared on the DPE since July 2021, and it is filled in 86.4% of the time. That figure deserves an explanation, because you often read that one certificate in three lacks it. That is true if you count every DPE in the database — but a large share of them are dwelling certificatesgenerated automatically from the building-level DPE, for which the regulation simply does not provide for a summer comfort assessment (annex 9 § 9.1). We exclude them: 4.2 million certificates, and most of the apparent gap. Once that correction is made, houses and flats turn out to be level — 86.5% against 86.4% — where the raw gap looked enormous.

Second finding: how the verdicts actually break down

Across the 9,663,670 certificates that do fill in the indicator, here is how the three levels break down.

Second finding: how the verdicts actually break down
Declared levelShare of completed certificates
Insufficient40.2%
Average43.2%
Good16.6%

These 40.2% are the indicator exactly as written on the certificates. We also re-applied the annex 9 rule ourselves to the five criteria recorded in each EPC: the share of "insufficient" then rises to 46.5%. The gap is not a matter of perimeter — it is that 16.4% of certificates display a verdict that does not match their own recorded characteristics. The two figures measure different things, and we publish both. Neither is weighted to represent the whole housing stock.

The blind spot: the rule scores the building, not the climate

Annex 9 assesses five characteristics of the home — external solar shading, roof insulation, thermal inertia, cross-ventilation, fixed ceiling fans. None of them depends on where the building stands. An identical house therefore receives the same verdict in Lille and in Menton. This is a deliberate property of the rule, not a hidden flaw: it measures what the building can do, independently of the climate load it faces.

But the effect on how regions rank is striking. We crossed the declared verdict with an internal score that adds local climate and the urban heat island effect. The ranking inverts: cities among the best scored by the rule turn out to be among the most exposed once real heat is taken into account. This is most visible along the Mediterranean coast, but it is not only a southern matter — Paris ranks 2nd of the 426 ranked municipalities, at 53 out of 100, combining a mediocre building stock with an urban heat island the rule ignores entirely.

The blind spot: the rule scores the building, not the climate
CityDeclared "insufficient" shareSummer Score (100 = most comfortable)
Mandelieu-la-Napoule21.4%58
Antibes22.3%58
Menton24.2%58
Nice24.2%58
Montpellier24.7%58

National median: 67. These five cities rank among the best-scored by the rule — beyond 390th out of the 426 cities with at least 3,000 certificates our volumes allow us to rank — and among the most exposed once climate is included. We publish the score rather than a rank: all five sit at exactly 58, within a group of 14 municipalities sharing that score. Separating them by rank would mean publishing the order of a sort, not a measured difference.

The reverse is true too

Roubaix has the worst "insufficient" share among the 426 cities our volumes allow us to rank, at 68.2%. Its building stock is genuinely to blame: older homes, little external shading. Once climate is factored in, the city joins the group of seventeen municipalities scoring 64, between the 102nd and 118th ranks out of those 426 — so it stays within the most exposed third, but far from the Mediterranean pack. A poor regulatory verdict therefore does not mechanically signal an unliveable summer, and a good verdict guarantees nothing on the French Riviera. That is the whole limitation of an indicator that only looks at the walls.

The mistakes that skew the test

  1. 1

    Counting internal shading

    The criterion only recognises protections placed outside the glazing — hinged or roller shutters, external blinds, overhangs, brise-soleil — on windows facing south, east or west, and on roof lights. North-facing windows are out of scope.

    What it changes: Blinds, curtains or films fitted inside do not count: by the time heat reaches them, it has already come through the glass. And this is an eliminating criterion — counting it wrongly is enough to move a verdict from "insufficient" to "average" or "good".

  2. 2

    Ticking "cross-ventilated" for a corner flat

    Windows on two façades are not always enough: the rule requires that no single orientation concentrates more than 75% of the glazed area. A corner flat whose openings nearly all face the same way is therefore not cross-ventilated. The test’s question is a simplification — your answer is taken as given, the test does not measure how the glazed areas are distributed.

    What it changes: A secondary criterion counted wrongly can move the result from "average" to "good". Only the certificate’s XML file, which carries the criterion as the assessor declared it, can settle the matter.

  3. 3

    Getting the floor wrong in a flat

    The home’s position in the building alone decides the fate of the roof criterion: on the ground floor or a middle floor it is neutralised; on the top floor or under the loft it becomes eliminating again and, absent a declared insulation quality, it is settled by the construction year — before 1975, the roof is deemed uninsulated.

    What it changes: When the certificate already carries the floor, that data prevails and your answer merely pre-fills it. So it is when the certificate is silent about the floor that an inaccurate answer can swing the verdict between "insufficient" and "good" without any other criterion changing.

  4. 4

    Confusing a fan with a fixed ceiling fan

    The criterion targets a permanently installed unit, typically a ceiling fan. A pedestal fan, a model set on a piece of furniture or an air cooler do not count. The question does not offer "I don’t know": it reads as "no" until you change it.

    What it changes: Answering "yes" wrongly adds a secondary criterion and can move the level from "average" to "good". Conversely, leaving the question untouched deprives you of the criterion if you really do have a ceiling fan.

  5. 5

    Reading a range as a verdict

    When a criterion is left at "I don’t know", the tool does not invent a value: if the answer could change the level, it shows a range, from worst to best case, rather than a verdict; if it cannot change anything, it settles the matter anyway.

    What it changes: Do not take the upper bound: the worst case is the prudent scenario. The Summer Score shown just below does not penalise an unknown criterion — it is therefore optimistic, and the confidence index beneath it drops to signal this. Importing the certificate’s XML file removes the ambiguity and returns a single level.

  6. 6

    Mistaking the estimate for the official EPC

    The test result is an estimate, including when you activate the "what if you did these works" levers. Fitting external shutters does not update the existing certificate: a new EPC is needed for the level to change officially.

    What it changes: Putting forward a level in a listing or a negotiation on the strength of the test alone has no legal value. Only an EPC issued by a certified assessor counts.

Sources and limitations

Regulatory indicator: order of 31 March 2021, annex 9. Declared figures computed on our national certificate database (category A), certificates issued since July 2021, restricted to houses and flats in mainland France — overseas territories and other building types are out of scope. Unweighted data, therefore not representative of the total housing stock: a certificate is mainly produced on a sale or a letting, which over-represents homes that change hands. The climate cross-reference relies on an internal score, computed on a 25% sample of that database and carrying no regulatory value: it complements the official indicator, it does not replace it. the full study · our methodology

Frequently asked questions

A home overheats in summer when it ticks the wrong boxes of annex 9: no external solar shading, a poorly insulated roof, low thermal mass and no cross-ventilation. Our free test applies this regulatory rule to your dwelling in about a minute — from your DPE number, your address or your XML file — and returns a three-level verdict.

The summer comfort indicator has appeared on every DPE since July 2021 (French order of 31 March 2021, annex 9). It rates the home on three levels — insufficient, medium or good — based on its ability to stay cool without air conditioning. It is purely informative: it does not affect the energy or climate label, but informs the buyer or tenant.

No. Air conditioning is not taken into account in the summer comfort indicator (French order of 31 March 2021, annex 9, §9.4): the indicator measures the passive comfort of the building fabric, without any active cooling equipment. Installing an air conditioner therefore does not change your level. The reduced 5.5% VAT on fixed reversible air conditioning (since July 2026) remains a separate measure, outside the indicator.

Four levers improve summer comfort: fitting external solar protections (shutters, blinds, overhangs) on the sun-exposed façades, insulating the roof or loft, encouraging cross-ventilation and installing fixed ceiling fans. On the funding side, everything now goes through MaPrimeRénov's guided pathway, since 1 September 2026: solar protections, fans and roof insulation alike. Only energy-saving certificates remain available measure by measure, for insulation.

Yes, though less often than commonly reported: about one certificate in seven. Two situations differ: the indicator may simply not have been filled in, or not be assessed at all — which is the regulatory case for a certificate issued at whole-building level, or for a flat generated from that building survey. In both cases, the test above reconstructs the level from the five annex 9 criteria.

Yes. A fully declarative mode lets you answer three questions — external solar protections, windows on at least two façades, fixed ceiling fan — with no document at all. The result will more often be a range than a clear-cut verdict, because thermal inertia and roof insulation cannot be inferred without a certificate. If your landlord has given you the EPC, its thirteen-character number is enough to sharpen the result.

Because there is no roof above your home. For a ground-floor or mid-floor flat, annex 9 does not retain this criterion: it displays as "not assessed" and is not held against you. A top-floor or loft flat is treated like a house — its roof insulation becomes an eliminating criterion again. The test can only neutralise it if it knows your position in the building, either from the EPC or from your answer about the floor.

No, it carries no regulatory value. It is a proprietary OneDpe method, indicative, which complements the official three-level indicator rather than replacing it. It adds what annex 9 does not look at: local climate, its 2030 projection and, since score version 0.5.0, the urban heat island effect resolved at address level. Across our observable sub-sample the median stands at 67 out of 100 — a median of unweighted certificates, which does not describe the housing stock.

No. The summer comfort indicator changes neither the energy label nor the climate label, and letting restrictions rest solely on that label, under energy decency rules: a G-rated home can no longer be the subject of a new lease or a renewal since 1 January 2025, class F from 1 January 2028 and class E from 1 January 2034 in mainland France (Act no. 2021-1104 of 22 August 2021, art. 160). Ongoing leases remain valid until their term. An "insufficient" summer comfort rating currently entails no restriction.